化工学报 ›› 2015, Vol. 66 ›› Issue (S1): 117-122.DOI: 10.11949/j.issn.0438-1157.20150306

• 流体力学与传递现象 • 上一篇    下一篇

局部强内热源移动球床温度分布特性

王永伟, 淮秀兰, 李勋锋, 蔡军, 席文宣   

  1. 中国科学院工程热物理研究所, 北京 100190
  • 收稿日期:2015-03-11 修回日期:2015-03-21 出版日期:2015-06-30 发布日期:2015-06-30
  • 通讯作者: 淮秀兰
  • 基金资助:

    国家自然科学基金项目(51376177)。

Temperature distribution characteristics in moving pebble bed with local internal heat generation

WANG Yongwei, HUAI Xiulan, LI Xunfeng, CAI Jun, XI Wenxuan   

  1. Institute of Engineering Thermophysics, Chinese Academy of Sciences, Beijing 100190, China
  • Received:2015-03-11 Revised:2015-03-21 Online:2015-06-30 Published:2015-06-30
  • Supported by:

    supported by the National Natural Science Foundation of China (51376177).

摘要:

球形颗粒的运动速度与局部强内热源移动球床通道内温度分布有着必然联系。通过理论推导分别得到了含有强内热源移动球床中球形颗粒运动速度与加热区出口和通道出口平均温度之间的关联式。运用数值方法获得了含有局部强内热源移动球床三维模型的温度分布, 通道出口温度的数值结果与理论关联式计算结果吻合良好, 两者相对误差小于8%。在此基础上, 进一步对比分析了3种不同运动速度下的内热源加热区出口温度、球床通道中心温度和出口温度的分布特点。通道中心温度沿颗粒运动方向先升高后降低, 最高温度出现在加热区出口处。随着颗粒运动速度增大, 内热源加热区出口温度、通道出口温度和通道中心温度逐渐降低且径向温度梯度也随之减小。

关键词: 内热源, 移动球床, 温度分布

Abstract:

The temperature distribution in the channel of moving pebble beds with the local internal heat generation is important factor for design and operation of many devices including heat exchangers, reactors and dryers. The particle velocity is the key for the temperature distribution and heat transfer in the channel of moving pebble beds with the local internal heat generation. The correlation between the particle velocity and the outlet average temperatures (T1 and T2) of the internal heat generation zone and channel were theoretically analyzed. The three-dimensional numerical simulation was performed on FLUENT using the k-e model for the same physical model of the theoretical analysis. The outlet average temperature of the channel is agreed with the theoretical correlation and the relative error is lower than 8%. Based on the three cases of particle velocities, the outlet temperature of the local internal heat generation zone, the channel outlet temperature and the channel centre temperature are compared, and the temperature distribution characteristics of whole channel are predicted and analyzed. The results show that the channel temperature increased first then decreased along the vertical axis downward, and the temperature maximum was located the outlet of the internal heat generation zone. The outlet temperature of internal heat generation zone, the channel outlet temperature, and the center temperature decreased with the particle velocity increasing.

Key words: internal heat source, moving pebble bed, temperature distribution

中图分类号: