CIESC Journal ›› 2010, Vol. 18 ›› Issue (3): 419-424.

• • 上一篇    下一篇

Adaptive On-line Operation Guide for Dry Gas-to-ethylbenzene Reactor

钱新华, 贾世阳, 苏兴, 陈悦, 王克峰, 姚平经   

  1. Institute of Chemical Process System Engineering, Dalian University of Technology, Dalian 116012, China
  • 收稿日期:2009-11-26 修回日期:2010-04-12 出版日期:2010-06-28 发布日期:2010-06-28
  • 通讯作者: WANG Kefeng,E-mail:dlwangkefeng@163.com

Adaptive On-line Operation Guide for Dry Gas-to-ethylbenzene Reactor

QIAN Xinhua, JIA Shiyang, SU Xing, CHEN Yue, WANG Kefeng, YAO Pingjing   

  1. Institute of Chemical Process System Engineering, Dalian University of Technology, Dalian 116012, China
  • Received:2009-11-26 Revised:2010-04-12 Online:2010-06-28 Published:2010-06-28

摘要: In this paper,a third-generation dry gas-to-ethylbenzene process in a factory of PetroChina is considered.For the gradual catalyst deactivation in the alkylation reactor,a model is established with the parameters estimated from the reaction rate equation of alkylation based on the on-site data and those from laboratory analysis. The real-time dynamic simulation of the alkylation process is carried out,in which the module accuracy is ensured by using OPC(Object linking and embedding for Process Control)technique and adaptive correction of model parameters.Both the current and future operation temperature can be predicted.

关键词: dry gas-to-ethylbenzene reactor, catalyst deactivation, OPC technology, adaptive correction of model parameter, online operation guide

Abstract: In this paper,a third-generation dry gas-to-ethylbenzene process in a factory of PetroChina is considered.For the gradual catalyst deactivation in the alkylation reactor,a model is established with the parameters estimated from the reaction rate equation of alkylation based on the on-site data and those from laboratory analysis. The real-time dynamic simulation of the alkylation process is carried out,in which the module accuracy is ensured by using OPC(Object linking and embedding for Process Control)technique and adaptive correction of model parameters.Both the current and future operation temperature can be predicted.

Key words: dry gas-to-ethylbenzene reactor, catalyst deactivation, OPC technology, adaptive correction of model parameter, online operation guide