CIESC Journal
• 传递现象 • 上一篇 下一篇
卷式反渗透膜器浓水侧流道缺陷诊断
杨庆峰
上海交通大学环境科学与工程学院,上海 200240
出版日期:
发布日期:
Diagnosis of membrane passage defects for reverse osmosis spiral wound membrane module
YANG Qingfeng
Online:
Published:
Abstract: Reverse osmosis (RO) desalination is universally recognized as the most cost effective technology for desalting both brackish water and sea-water.The design of the vast majority of RO desalination plants is based on spiral wound membrane modules.Though spiral wound modules show overall favorable performance, there is still much room for improving their flow performance and thereby lowering water costs.Improved module design could be achieved by better understanding of the geometric and operating parameters that determine the complex flow patterns in a spiral wound module.It is widely recognized that flow maldistribution can have a negative impact on module performance.Residence time distribution (RTD) tests have a potential for on-line detection of such defects. In the present study, RTD techniques were used to characterize the degree of uniformity of flow in the membrane passages and diagnose flow distribution defects.RTD data showed that feed pressure had no effect at all on the magnitude of the dispersion coefficient indicating no distortion of the flow passages by pressure increase.Significant deviation from ideal plug flow was found in the laboratory size and industrial size RO systems.In both systems, the dispersion coefficient increased roughly linearly with the Reynolds number.
杨庆峰 .
YANG Qingfeng.
导出引用管理器 EndNote|Ris|BibTeX
链接本文: https://hgxb.cip.com.cn/CN/
https://hgxb.cip.com.cn/CN/Y2006/V57/I6/1319