淋降塔内非牛顿流体的传质研究

褚家瑛,唐寅南,江体乾   

  1. 华东化工学院 ,华东化工学院 ,华东化工学院
  • 出版日期:1986-12-25 发布日期:1986-12-25

Mass Transfer in Dripping Plate Column for Non-Newtonian Fluids

Chu Jiaying, Tang Yingnan and Jiang Tiqian (East China Institute of Chemical Technology)   

  • Online:1986-12-25 Published:1986-12-25

摘要: 本文研究非牛顿幂律流体传质过程,实验采用淋降塔装置,测定高聚物溶液的传质速率.实验结果表明传质速率随温度和溶液流量增加而增大,还随压力和溶液稠度系数下降而增加.并应用相似论原理分析非牛顿幂律流体传质过程,得到柯尔本因子与雷诺数关系式j_m=BRe~B_1,由实验数据经线性回归得到B=2.2708×10~(-5),B_1=-0.7013相关系数0.99.

Abstract: A dripping plate column fitted with perforated trays was used in studying the mass transfer for non-Newtonian liquids. The rate of vaporization of aqueous polymer solutions rheological behavior with power-law was measured in the column. It was found that temperature, pressure, mass flow rate and the non-Newtonian behavior of the solution are significant factors influencing mass transfer rate, which increases with increasing temperature and mass flow rate, and with decreasing pressure and fluid consistency. Based on these experimental data, a correlation for the Colburn factor, jm, was developed: jm= 2.2708 × 10-5Re-0.7013 It can be used to design flash columns for monomer discharge from polymer solutions.