CIESC Journal

• 化工学报 • 上一篇    下一篇

测量仪表过失误差的单结点识别方法

王希若,荣冈   

  1. 浙江大学工业控制技术国家重点实验室!杭州310027,浙江大学工业控制技术国家重点实验室!杭州310027
  • 出版日期:2000-02-25 发布日期:2000-02-25

APPROACH TO GROSS ERROR IDENTIFICATION OF INSTRUMENTS BASED ON RESIDUAL OF SINGLE NODE

Wang Xiruo and Rong Gang (National Laboratory of Industrial Control Technology, Zhejiang University, Hangzhou 310027)   

  • Online:2000-02-25 Published:2000-02-25

摘要: 提出了一种新的过失误差识别方法 ,即结合仪表的可靠度、精度等级等信息 ,利用单结点的约束残差进行过失误差识别 .给出仿真实例 ,通过与其他几种常用的误差识别方法对比对这一方法进行了评价 .

Abstract: The problem of gross error detection and identification becomes the bottleneck of data reconciliation A new approach to gross error identification based on the reliability, precision ranking of the flowmeters as well as the residual of single node is presented It is assumed that the measurement error independently tends toward normal distribution and the reliability of every flowmeter is no lower than its lower limit The distribution of probability density for different situations of gross error at a single node is edfined The computation procedure for the different probabilities is given by using reliability and precision information of the instrument in/out a node and the residual of the node. Then the magnitude of different probabilities can be used as the criteria for gross error identification Two simulations are given and a comparison is made between the new approach and previous researches It is shown that the proposed method is quite effective in gross error identification especially when the system comprises of a relatively large number of flows

中图分类号: