CIESC Journal

• RESEARCH NOTES • 上一篇    

低己内酰胺浓度下水-己内酰胺-苯体系的液液平衡及硫酸铵对平衡的影响

刘建青; 谢方友; 何潮洪; 朱明乔   

  1. Department of Chemical Engineering, Zhejiang University, Hangzhou 310027, China
  • 收稿日期:1900-01-01 修回日期:1900-01-01 出版日期:2002-06-28 发布日期:2002-06-28
  • 通讯作者: 刘建青

Recovery of Caprolactam from Waste Water in Caprolactam Production Using Pulsed-sieve-plate
Extraction Column

LIU Jianqing; XIE Fangyou; HE Chaohong; ZHU Mingqiao   

  1. Department of Chemical Engineering, Zhejiang University, Hangzhou 310027, China
  • Received:1900-01-01 Revised:1900-01-01 Online:2002-06-28 Published:2002-06-28
  • Contact: LIU Jianqing

摘要: Recovery of caprolactam from waste water of caprolactam production factory was investigated
using benzene as solvent in a small-scale pulsed-sieve-plate column. First, liquid-liquid
equilibrium (LLE) data were measured, including water-caprolactam-benzene system at low
caprolactam concentrations, and waste water-benzene system. Then, the operating regions and
mass transfer of the pulsed-sieve-plate column were measured. Finally,the overall apparent
heights of a transfer unit based on continuous phase are correlated in terms of the column
operation variables.

关键词: pulsed-sieve-plate column;extraction;ε-caprolactam;waste water

Abstract: Recovery of caprolactam from waste water of caprolactam production factory was investigated
using benzene as solvent in a small-scale pulsed-sieve-plate column. First, liquid-liquid
equilibrium (LLE) data were measured, including water-caprolactam-benzene system at low
caprolactam concentrations, and waste water-benzene system. Then, the operating regions and
mass transfer of the pulsed-sieve-plate column were measured. Finally,the overall apparent
heights of a transfer unit based on continuous phase are correlated in terms of the column
operation variables.

Key words: pulsed-sieve-plate column, extraction, ε-caprolactam, waste water