CIESC Journal

• SELECTED PAPERS IN COMMEMORATE • 上一篇    下一篇

陶瓷过滤器脉冲反吹系统的流场的数值模拟

姬忠礼; 彭书; 谭立村   

  1. Department of Chemical Engineering, University of Petroleum, Beijing,102249, China
  • 收稿日期:1900-01-01 修回日期:1900-01-01 出版日期:2003-12-28 发布日期:2003-12-28
  • 通讯作者: 姬忠礼

Numerical Analysis of Flow Field in Ceramic Filter During Pulse Cleaning

JI Zhongli; PENG Shu; TAN Licun   

  1. Department of Chemical Engineering, University of Petroleum, Beijing,102249, China
  • Received:1900-01-01 Revised:1900-01-01 Online:2003-12-28 Published:2003-12-28
  • Contact: JI Zhongli

摘要: In the commercial utilization of rigid ceramic filters, the performance of pulse cleaning
has crucial effects on the long-term stable operation. In order to get a clear insight into
the nature of this cleaning process and provide a solid basis for industrial applications,
the flow in ceramic candle filter was investigated. The flow in the pulse-jet space and
inside the ceramic candle is regarded as two- dimensional, unsteady, compressible flow, and
numerical simulation is carried out by computational fluid dynamics. The numerical
predictions of flow field are in good agreement with the experimental measurements. Effects
of the candle diameter, the separation distance between the nozzle and the candle injector
and the length of the candle on the flowfield have been numerically analyzed to provide the
basis for the optimum design of the pulse cleaning system.

关键词: numerical simulation;unsteady flowfield;ceramic candle;pulse cleaning

Abstract: In the commercial utilization of rigid ceramic filters, the performance of pulse cleaning
has crucial effects on the long-term stable operation. In order to get a clear insight into
the nature of this cleaning process and provide a solid basis for industrial applications,
the flow in ceramic candle filter was investigated. The flow in the pulse-jet space and
inside the ceramic candle is regarded as two- dimensional, unsteady, compressible flow, and
numerical simulation is carried out by computational fluid dynamics. The numerical
predictions of flow field are in good agreement with the experimental measurements. Effects
of the candle diameter, the separation distance between the nozzle and the candle injector
and the length of the candle on the flowfield have been numerically analyzed to provide the
basis for the optimum design of the pulse cleaning system.

Key words: numerical simulation, unsteady flowfield, ceramic candle, pulse cleaning