CIESC Journal

• SEPARATION SCIENCE & ENGINEERING • 上一篇    下一篇

新型多管塔流体力学特性

张鹏飞;黄万福; 池红卫; 王树楹   

  1. Chemical Engineering Research Center, Tianjin University, Tianjin 300072, China
  • 收稿日期:1900-01-01 修回日期:1900-01-01 出版日期:2006-08-28 发布日期:2006-08-28
  • 通讯作者: 张鹏飞

Liquid Flow Distribution in a New Type of Multi-tube Column

ZHANGPengfei; HUANGWanfu; CHIHongwei; WANGShuying   

  1. Chemical Engineering Research Center, Tianjin University, Tianjin 300072, China
  • Received:1900-01-01 Revised:1900-01-01 Online:2006-08-28 Published:2006-08-28
  • Contact: ZHANG Pengfei

摘要: A new type of multi-tube column, in which a novel internal-structure is installed in the bed of random packing, has been invented. The internal-structure reduces the hydraulic radius of the column and adjusts the gas/liquid flow so that the liquid maldistribution is greatly abated. A mathematical model with boundary conditions based on close-open mechanism at the internal-structure was established to study the hydraulic behavior of such a column and experiments were carried out to verify the applicability of the model. Predictions from the model agreed well with experimental results. The optimal ratio of the hydraulic diameter of the new multi-tube column to the packing element diameter is found to be 17.5 to 23.3 by employing the optimization method of nonlinear programming. And this new type of multi-tube column opens a new way for random packing columns to be scaled up for industry.

关键词: multi-tube column;internal-structure;liquid distribution;mathematical model;close-open mechanism;optimization

Abstract: A new type of multi-tube column, in which a novel internal-structure is installed in the bed of random packing, has been invented. The internal-structure reduces the hydraulic radius of the column and adjusts the gas/liquid flow so that the liquid maldistribution is greatly abated. A mathematical model with boundary conditions based on close-open mechanism at the internal-structure was established to study the hydraulic behavior of such a column and experiments were carried out to verify the applicability of the model. Predictions from the model agreed well with experimental results. The optimal ratio of the hydraulic diameter of the new multi-tube column to the packing element diameter is found to be 17.5 to 23.3 by employing the optimization method of nonlinear programming. And this new type of multi-tube column opens a new way for random packing columns to be scaled up for industry.

Key words: multi-tube column, internal-structure, liquid distribution, mathematical model, close-open mechanism, optimization