化工学报 ›› 2015, Vol. 66 ›› Issue (2): 530-536.DOI: 10.11949/j.issn.0438-1157.20140861

• 流体力学与传递现象 • 上一篇    下一篇

低熔点熔盐圆管内强迫对流换热

刘闪威1, 吴玉庭1, 崔武军1, 熊亚选2, 陈夏1, 鹿院卫1, 马重芳1   

  1. 1 北京工业大学传热强化与过程节能教育部重点实验室暨传热与能源利用北京市重点实验室, 北京 100124;
    2 北京建筑工程学院供热、供燃气、通风及空调工程北京市重点实验室, 北京 100044
  • 收稿日期:2014-06-09 修回日期:2014-11-15 出版日期:2015-02-05 发布日期:2015-02-05
  • 通讯作者: 吴玉庭
  • 基金资助:

    国家自然科学基金国际(地区)合作与交流项目(51361135702);国家重点基础研究发展计划项目(2011CB707202)。

Forced convection heat transfer with low-melting point molten salt in circular pipe

LIU Shanwei1, WU Yuting1, CUI Wujun1, XIONG Yaxuan2, CHEN Xia1, LU Yuanwei1, MA Chongfang1   

  1. 1 Key Laboratory of Enhanced Heat Transfer and Energy Conservation of Ministry of Education, Key Laboratory of Heat Transfer and Energy Conversion of Beijing Municipality, Beijing University of Technology, Beijing 100124, China;
    2 Key Laboratory of HVAC, Beijing University of Civil Engineering and Architecture, Beijing 100044, China
  • Received:2014-06-09 Revised:2014-11-15 Online:2015-02-05 Published:2015-02-05
  • Supported by:

    supported by the International and Exchange of the National Natural Science Foundation of China (51361135702) and the National Basic Research Program of China (2011CB707202).

摘要:

熔融盐具有使用温度高、热稳定性和传热性能好等优点,被认为是太阳能热发电系统中最有前途的传热、蓄热介质之一。通过搭建槽式太阳能熔盐集热传热实验台,进行了低熔点熔盐管内受迫对流换热实验,获得了不同熔盐流速下套管式熔盐-水传热单元的总传热系数;通过最小二乘法获得了低熔点熔盐管内充分发展紊流段对流换热Nusselt数随Reynolds数的变化曲线和实验关联式,并与经典关联式进行了对比,结果表明,实验数据和Dittus-Boelter方程、Colburn方程、Seider-Tate方程以及Gnielinski方程最大偏差分别为+23%、+13%、-10%和-20%,实验数据和经典公式符合较好。

关键词: 低熔点熔盐, 强迫对流, 对流传热系数

Abstract:

Molten salt as one of the most promising heat transfer and heat storage media in the concentrating solar power (CSP) system has such advantages as high and wide liquid temperature, good heat transfer performance, low operation pressure and good thermal stability. An experimental study on turbulent convective heat transfer with low-melting point molten salt in a circular tube was conducted by using a self-made parabolic trough solar collecting and heat transfer system with molten salt. The total heat transfer coefficients from water to salt in a concentric tube heat exchanger at different flow rates were obtained. The change of Nusselt number of low-melting point molten salt with Reynolds number was calculated with the least-square method and the experimental correlation were obtained. Comparison was also made between experimental data and well-known convective heat transfer correlations, with the maximum deviations between the present data and curves predicted by Dittus-Boelter, Colburn, Seider-Tate, and Gnielinski equations of +23%, +13% -10% and -20% respectively.

Key words: low-melting point molten salt, forced convection, convective heat transfer coefficient

中图分类号: