• 化工学报 •     Next Articles

STUDIES ON PACKED BED ELECTROCHEMICAL REACTORS ( I ) EXPERIMENTAL STUDY

Xu Wenlin, Liu Hezhou and Yuan Weikang (UNILAB Research Center of Chemical Reaction Engineering, East China University of Chemical Technology, Shanghai 200237)   

  • Online:1993-08-25 Published:1993-08-25

固定床电化学反应器研究(Ⅰ)床层内电势分布的实验测定

许文林,刘河洲,袁渭康   

  1. 华东化工学院联合化学反应工程研究所,华东化工学院联合化学反应工程研究所,华东化工学院联合化学反应工程研究所 上海200237.太原工业大学化工系 ,上海200237 ,上海200237

Abstract: An experimental set up which can be used to measure the potential distribution in a packed bed electrochemical reactor by an automatic data collection system was installed. Experiments were carried out to check with the model presented in the literature[2,3] of the study. The experimental data are in good agreement with the model calculations. The mentioned model is verified to be a general one which can be used for different operating regimes. The factors effecting on the potential distribution in the packed bed is also discussed.

摘要: 建立了测定固定床电化学反应器床层内电势分布的实验装置,由计算机采样测定了床层内的电势分布,并将实验结果与文献中的模型计算结果进行了比较,证明了文献所建立的反应器模型和模型方程求解方法的正确性.在不同操作模式下用实验方法考察了各因素对床层内电势分布的影响.