• 传递现象 • Previous Articles     Next Articles

FEATURES OF OXYGEN TRANSFER IN WATER AND RESTAURANT WASTEWATER IN BUBBLING PACKED TOWER

ZOU Huasheng;CHEN Huanqin   

  • Online:2003-08-25 Published:2003-08-25

鼓泡填料塔中水与餐厅污水氧传递特征

邹华生;陈焕钦   

  1. 华南理工大学化工学院,广东 广州 510640

Abstract: The features of oxygen transfer in water and restaurant wastewater in bubbling packed tower were studied theoretically and experimentally. Equations for calculating liquid-phase volumetric oxygen transfer coefficient in the bubbling packed tower were obtained by defining the rate of interface renewal and correlating experimental data. The deviation of calculated values from the experimental result is within 20%. The results showed that the new-style combined packing is superior to the other kinds of packing in oxygen transfer,and the comparison of oxygen transfer in water with that in restaurant wastewater under the same conditions showed that volumetric oxygen transfer coefficients in restaurant wastewater is smaller than those in water.

摘要: 用不稳定传质模型对鼓泡填料塔中水和污水氧传递进行了理论分析,通过定义表面更新速率和含气率导出了鼓泡填料塔中水和污水中氧传递系数与操作条件和填料特征之间的关系式,并通过实验确定了关系式中特征参数.用关系式计算得到的氧传递系数与实测值基本吻合,最大偏差为20%.结果表明:采用的组合型填料具有优良的氧传递性能;在相同操作条件下餐厅污水中的氧传递系数小于清水中的数值.