Abstract:
An indirect expansion technique was proposed to measure the gas holdup in a non-transparent bubble column with 0.1 m inner diameter and height of 5.2 m.Air and distilled water were employed as gas and liquid phases, respectively.The experimental results show that the average and maximum errors of gas holdup are less than 2% and 4.5%, respectively, between the indirect expansion and pressure drop methods at atmospheric or elevated pressure.Moreover, the gas holdup increases with operating pressure when the superficial gas velocity is a constant, while the effect of static liquid height on gas holdup can be ignored when the operating pressure and superficial gas velocity are fixed.
Key words: 鼓泡床, 气含率, 间接膨胀法, 差压法
鼓泡床,
关键词: 鼓泡床, 气含率, 间接膨胀法, 差压法
WANG Lixiang, WU Guiying, LI Yang, QI Nana, ZHANG Kai. Gas holdup measurement of bubble column using indirect expansion technique[J]. CIESC Journal, 2010, 61(9): 2353-2357.
王丽祥, 吴桂英, 李阳, 齐娜娜, 张锴. 采用间接膨胀法研究鼓泡床内气含率特性 [J]. 化工学报, 2010, 61(9): 2353-2357.