HU Xuhui,ZHAO Xuhui,ZUO Yu,TANG Yuming" />
• 材料化学工程与纳米技术 • Previous Articles
HU Xuhui,ZHAO Xuhui,ZUO Yu,TANG Yuming
Online:
Published:
胡旭晖,赵旭辉,左禹,唐聿明
Abstract:
The failure process of epoxy-coated rebars under different magnitudes of loads in simulated concrete pore solution with chloride ions was studied by electrochemical impedance spectrum(EIS)technology.The results showed that coating resistance of the sample under load declined, and water absorption increased obviously.The higher the load was, the faster the failure of the sample would be.The coating water absorption test result was consistent with that of EIS.In addition, the applied load made the coating adhesion of the sample decline, and the adhesion decreased more obviously under a higher load.Therefore, the increase of coating porosity and the decrease of coating adhesion under applied load were the main reasons leading to the degradation of coating protective performance.
HU Xuhui,ZHAO Xuhui,ZUO Yu,TANG Yuming. Influence of applied load on failure of epoxy coated rebar in simulated concrete pore solution[J]. .