HU XuhuiZHAO XuhuiZUO YuTANG Yuming" /> <SPAN style="FONT-FAMILY: Times New Roman,serif; FONT-SIZE: 10.5pt; mso-font-kerning: 1.0pt; mso-bidi-font-size: 11.0pt; mso-ansi-language: EN-US; mso-fareast-language: ZH-CN; mso-bidi-language: AR-SA; mso-fareast-font-family: 宋体" lang=EN-US><FONT color=#000000>Influence of applied load on failure of epoxy coated rebar in simulated concrete pore solution</FONT></SPAN>

• 材料化学工程与纳米技术 • Previous Articles    

Influence of applied load on failure of epoxy coated rebar in simulated concrete pore solution

HU XuhuiZHAO XuhuiZUO YuTANG Yuming   

  • Online:2011-09-05 Published:2011-09-05

外加应力对钢筋/环氧涂层体系在模拟孔隙液中失效的影响

胡旭晖,赵旭辉,左禹,唐聿明   

  1. 北京化工大学材料科学与工程学院,北京100029

Abstract:

The failure process of epoxy-coated rebars under different magnitudes of loads in simulated concrete pore solution with chloride ions was studied by electrochemical impedance spectrum(EIS)technology.The results showed that coating resistance of the sample under load declined, and water absorption increased obviously.The higher the load was, the faster the failure of the sample would be.The coating water absorption test result was consistent with that of EIS.In addition, the applied load made the coating adhesion of the sample decline, and the adhesion decreased more obviously under a higher load.Therefore, the increase of coating porosity and the decrease of coating adhesion under applied load were the main reasons leading to the degradation of coating protective performance.