化工学报 ›› 2012, Vol. 63 ›› Issue (S2): 85-88.DOI: 10.3969/j.issn.0438-1157.2012.z2.016

• 过程系统工程 • 上一篇    下一篇

基于主元分析法的冷水机组传感器故障检测效率分析

胡云鹏1, 陈焕新1, 周诚1, 杨小双1, 徐荣吉2   

  1. 1. 华中科技大学环境科学与工程学院, 湖北 武汉 430074;
    2. 北京建筑工程学院 供热供燃气通风及空调工程北京市重点实验室, 北京 100044
  • 收稿日期:2012-09-29 修回日期:2012-10-11 出版日期:2012-12-28 发布日期:2012-12-28
  • 通讯作者: 陈焕新
  • 作者简介:胡云鹏(1978-),男,博士研究生。
  • 基金资助:

    "十一五"国家科技支撑计划项目(2008BAJ12B03);供热供燃气通风及空调工程北京市重点实验室研究基金资助课题(NR2012K06);2010年度湖北省建设科技项目;2011年度湖北省建设科技项目。

Analysis of sensor fault detection in chiller based on PCA method

HU Yunpeng1, CHEN Huanxin1, ZHOU Cheng1, YANG Xiaoshuang1, XU Rongji2   

  1. 1. School of Environmental Science and Engineering, Huazhong University of Science & Technology, Wuhan 430074, Hubei, China;
    2. Beijing Key Laboratory of Heating, Gas Supply, Ventilating and Air Conditioning Engineering, Beijing University of Civil Engineering and Architecture, Beijing 100044, China
  • Received:2012-09-29 Revised:2012-10-11 Online:2012-12-28 Published:2012-12-28
  • Supported by:

    supported by the National Key Technology R&D Program in the 11th Five Year Plan of China(2008BAJ12B03),the Beijing Key Lab of Heating,Gas Supply,Ventilating and Air Conditioning Engineering(NR2012K06),the 2010 and 2011 Science and Technology Planning Projects of Department of Housing and Urban-Rural Development of Hubei Province.

摘要: 冷水机组是一个高度非线性的复杂系统,其自控系统传感器故障会导致冷水机组的运行偏离正常状态和能耗浪费。采用冷水机组正常运行数据,通过多元统计方法中的主元分析法建立训练矩阵,利用平方预测误差进行故障分析工作。引入不同程度故障,分析主元分析法的检测效率。结果表明,主元分析法故障检测效果明显,但对于不同传感器的不同程度故障,故障检测的误判率存在一定的差异。

关键词: 冷水机组, 故障检测, 主元分析, 检测效率

Abstract: Chiller is a highly nonlinear complex system.The sensor fault in the automation system of chiller will cause it to operate in unmoral situation and waste energy.Based on the principal component analysis(PCA)method,one of the analytical methods in multivariate statistics,the data in normal condition have been used to establish the train matrix.The square prediction error(SPE)has been used to analyze the sensor fault.The detection efficiency has been analyzed by the PCA method with introducing different level faults into the chiller.The result shows that PCA-based fault detection method works well,but the fault detection efficiencies of different sensors with different level faults are inconsistent.

Key words: chiller, fault detection, principal component analysis, detection efficiency