• TRANSPORT PHENOMENA & FLULD MECHANICS • Previous Articles     Next Articles

Experimental Research on Flow Maldistribution in Plate-Fin Heat Exchangers

ZHANG Zhe; LI Yanzhong; XU Qing   

  1. School of Energy and Power Engineering, Xi'an Jiaotong University, Xi'an 710049, China
  • Received:1900-01-01 Revised:1900-01-01 Online:2004-02-28 Published:2004-02-28
  • Contact: ZHANG Zhe

板翘式换热器物流分配特性的实验研究

张哲; 厉彦忠; 许箐   

  1. School of Energy and Power Engineering, Xi'an Jiaotong University, Xi'an 710049, China
  • 通讯作者: 张哲

Abstract: The flow maldistribution and the effect of different inlet configuration on the flow
distribution in platefin heat exchangers were studied experimentally. It is found that the
flow maldistribution is serious because of the defects of inlet configurations, while the
inlet configuration and Reynolds number are the main factors affecting the flow
distribution. The improved inlet configurations, which are the header with a two-stage
distributing configuration and the guide vane with a fluid complementary cavity were
proposed and tested in this paper. The experimental results show that the improved inlet
configurations can effectively improve the performance of flow distribution in heat
exchangers.

Key words: plate-fin heat exchanger, flow distribution, inlet configuration

摘要: The flow maldistribution and the effect of different inlet configuration on the flow
distribution in platefin heat exchangers were studied experimentally. It is found that the
flow maldistribution is serious because of the defects of inlet configurations, while the
inlet configuration and Reynolds number are the main factors affecting the flow
distribution. The improved inlet configurations, which are the header with a two-stage
distributing configuration and the guide vane with a fluid complementary cavity were
proposed and tested in this paper. The experimental results show that the improved inlet
configurations can effectively improve the performance of flow distribution in heat
exchangers.

关键词: plate-fin heat exchanger;flow distribution;inlet configuration