[1] |
Gu Weizao (顾维藻). Heat Transfer Enhancement (强化传热) [M]. Beijing: Science Press, 1990.
|
[2] |
Lin Zonghu (林宗虎), Wang Jun (汪军), Li Ruiyang (李瑞阳). Heat Transfer Enhancement Technology (强化传热技术) [M]. Beijing: Chemical Industry Press, 2007.
|
[3] |
Li Jun'an (李军安), Xing Guiju (刑贵菊), Zhou Liwen (周丽雯). Progress in study on technology of heat transfer enhancement for heat exchanger [J]. Energy for Metallurgical Industry (冶金能源), 2008, (1): 50-54.
|
[4] |
Chen Jianbo (陈剑波), Cai Zuhui (蔡祖恢), Ding Yiming (丁一鸣). Study on boiling heat transfer of R12 flowing inside horizontal smooth [J]. Journal of Shanghai Institute of Mechanical (上海机械学院学报), 1992, 14 (30): 1-10.
|
[5] |
Hideyuki Kimura, Masaaki Ito. Evaporating heat transfer in horizontal internal spiral-grooved tubes in the region of low flow rates [J]. Bulletin of the JSME, 1981, 24 (195):1602-1607.
|
[6] |
Timothy A Shedd, Ty A Newell. Visualization of two-phase flow through micro grooved tubes for understanding enhanced heat transfer [J]. International Journal of Heat and Mass Transfer, 2003, 46: 4169-4177.
|
[7] |
Timothy A Shedd, Ty A Newell, Pei Keow Lee. The effects of the number and angle of microgrooves on the liquid film in horizontal annular two-phase flow [J]. International Journal of Heat and Mass Transfer, 2003, 46: 4179-4189.
|
[8] |
Zhou Jie (周杰), Xin Mingdao (辛明道). Two-phase flow pattern in three-dimensional rib tube flow boiling heat transfer [J]. Journal of Chongqing University (重庆大学学报), 2003, 26 (8): 109-113.
|
[9] |
Akhavan-Behabadi M A, Mohseni S G, Najafi H, et al. Heat transfer and pressure drop characteristics of force convective evaporation in horizontal tubes with coiled wire inserts [J]. International Communications in Heat and Mass Transfer, 2009, 36: 1089-1095.
|
[10] |
Murata K, Hashizume K. Forced convective boiling of nonazeotropic refrigerant mixtures inside tubes [J]. Heat Transfer-JapRes, 1990, 19 (2): 95-109.
|
[11] |
Eckels S J, Pate M B. An experimental comparison of evaporation and condensation heat transfer coefficients for HFC-134a and CFC-12 [J]. Int. J. Refrigeration, 1991, 14 (3): 70-77.
|
[12] |
Oh Se-Yoon, Bergles Arthur E. Experimental study of the effects of the spiral angle on evaporative heat transfer enhancement in micro-fin tubes [J]. ASHRAE Transactions, 1998, 19 (1): 1137-1143.
|
[13] |
Zhang Yifan (张一帆), Li Huixiong (李会雄), Zhang Yuqian (张煜乾). The influence of internally ribbed tube geometry on pipe flow resistance [J]. Journal of Engineering Thermophysics(工程热物理学报), 2011, 32 (7): 1161-1164.
|
[14] |
Zhang Xiaoyan (张小艳), Yuan Xiuling (袁秀玲), Tian Huanzhang (田怀璋). Evaporation heat transfer of R417A flowing inside horizontal smooth and internally grooved tubes [J]. Journal of Xi'an Jiaotong University (西安交通大学学报), 2007, 41 (1): 18-22.
|
[15] |
Cheng Jian (程建), Tao Leren (陶乐仁), Wei Yiping (魏义平). Experimental study on evaporation heat transfer of R410A and R22 in a rifled tube [J]. Fluid Machinery (流体机械), 2013, 41 (3): 54-57.
|
[16] |
Akhavan-Behabadi M A,Ravi Kumar, Jamali M. Investigation on heat transfer and pressure drop during swirl flow boiling of R134a in a horizontal tube [J]. International Journal of Heat and Mass Transfer, 2009, 52:1918-1927.
|
[17] |
Liu Rong (刘荣), Tao Leren (陶乐仁), Gao Libo (高立博). Experimental study on boiling heat transfer of R410A without lubricant oil in the inner-grooved copper tubes [J]. Journal of Refrigeration (制冷学报), 2011, 32 (4): 20-24.
|
[18] |
Kuo C S, Wang C C. In tube evaporation of HCFC-22 in a 9.52mm micro-fin/smooth tube [J]. Int. J. Heat Mass Transfer, 1996, 39 (12): 2559-2569.
|
[19] |
Kimura Hideyuki, Ito Masaaki. Evaporating heat transfer in horizontal internal spiral-grooved tubes in the region of low flow rates [J]. Bulletin of the JSME, 1981, 195 (24): 1602-1607.
|
[20] |
Muzzio A, Niro A, Arosio S. Heat transfer and pressure drop during evaporation and condensation of R22 inside 9.52mm O.D.microfin tubes of different geometries [J]. Enhanced Heat Transfer, 1998, (5): 39-52.
|
[21] |
Kubanek G R, Miletti D L. Evaporative heat transfer and pressure drop performance of internally-finned tubes with refrigerant 22 [J]. J. Heat Transfer, 1979, 101: 447-452.
|