化工学报 ›› 2014, Vol. 65 ›› Issue (z2): 235-239.DOI: 10.3969/j.issn.0438-1157.2014.z2.035

• 能源和环境工程 • 上一篇    下一篇

热水型PV/T组件结构参数的敏感性分析

孙亮亮1, 袁艳平1, 胡文举2, 曹晓玲1, 雷波1   

  1. 1. 西南交通大学机械工程学院, 四川 成都 610031;
    2. 北京建筑大学供热供燃气通风及空调工程北京市重点实验室, 北京 100044
  • 收稿日期:2014-09-02 修回日期:2014-09-10 出版日期:2014-12-30 发布日期:2014-12-30
  • 通讯作者: 袁艳平
  • 基金资助:

    中央高校基本科研业务费专项资金;供热供燃气通风及空调工程北京市重点实验室研究基金项目(NR2013K08)。

Sensitivity analysis of configuration parameters of water-type PV/T module

SUN Liangliang1, YUAN Yanping1, HU Wenju2, CAO Xiaoling1, LEI Bo1   

  1. 1. School of Mechanical Engineering, Southwest Jiaotong University, Chengdu 610031, Sichuan, China;
    2. Beijing Key Lab of Heating, Gas Supply, Ventilating and Air Conditioning Engineering, Beijing University of Civil Engineering and Architecture, Beijing 100044, China
  • Received:2014-09-02 Revised:2014-09-10 Online:2014-12-30 Published:2014-12-30
  • Supported by:

    supported by the Fundamental Research Funds for the Central Universities and Beijing Key Lab of Heating, Gas Supply, Ventilating and Air Conditioning Engineering (NR2013K08).

摘要:

采用归一化敏感系数法对热水型PV/T组件的主要结构参数(盖板玻璃厚度、空气腔厚度、集热板厚度、水管直径、水管间距和保温材料厚度)进行了敏感性分析。研究了太阳辐射值、室外温度和流速对各结构参数敏感系数的影响规律。结果表明,盖板玻璃厚度、水管直径和水管间距是影响热水型PV/T组件发电量和热水得热量的显著性参数。与太阳辐射值和流速相比,室外温度对结构参数的敏感系数影响不明显。

关键词: 热水型PV/T组件, 敏感性分析, 结构参数, 归一化敏感系数法

Abstract:

The sensitivity analysis of main configuration parameters of water-type PV/T module including thickness of cover glass, thickness of air gap, thickness of thermal absorber, diameter of water tube, spacing of water tube and thickness of thermal insulation material has been conducted using normalized sensitivity coefficient method. The impact of solar radiation, outdoor air temperature and flow rate on sensitivity coefficients of these configuration parameters are also investigated. It indicates that thickness of cover glass, diameter of water tube and spacing of water tube are significant influence parameters in term of electrical power generation and thermal heat for hot water. Compared with solar radiation and flow rate, effect of outdoor air temperature on sensitivity coefficients is not obvious.

Key words: water-type PV/T module, sensitivity analysis, configuration parameter, normalized sensitivity coefficient method

中图分类号: