[1] |
Chung T W, Lai C H, Wu Honda. Analysis of mass transfer performance in an air stripping tower[J].Separation Science and Technology, 1999, 34(14): 2837-2851
|
[2] |
Nielsen C H E, Kill S, Thomsen H W, Dam-Johansen K. Mass transfer in wetted-wall column: correlations at high Reynolds numbers[J].Chem. Eng. Sci., 1998, 53(3): 495-503
|
[3] |
Oberg V, Goswami D Y. Experimental study of the heat and mass transfer in a packed bed liquid desiccant air dehumidifier[J]. Journal of Solar Energy Engineering-Transaction of the ASME,1988, 120(4): 289-297
|
[4] |
Chung T W, Ghosh T K, Hines A L.Comparison between random and structured packings for dehumidification of air by lithium chloride solution and their heat and mass transfer correlations[J].Industrial and Engineering Chemistry Research, 1996, 35(1): 192-198
|
[5] |
LofGOG, Lenz T G, Rao S. Coefficients of heat and mass transfer in a packed bed suitable for solar regeneration of aqueous lithium chloride solution[J]. ASME J. Solar Energy Eng., 1984, 106: 387
|
[6] |
Abdul-Wahab S A, Abu-Arabi M K, Zurigat Y H. Effect of structured packing density on performance of air dehumidifier[J]. Energy Conversion and Management, 2004, 45(15/16): 2539-2552
|
[7] |
Fumo N, Goswami D Y. Study of an aqueous lithium chloride desiccant system: air dehumidification and desiccant regeneration[J]. Solar Energy, 2002, 72(4): 351-361
|
[8] |
Marin V, Goswami D Y. Heat and mass transfer in packed bed liquid desiccant regenerators—an experimental investigation[J]. Transactions of the ASME Journal of Solar Energy Engineering, 1999, 121: 162-170
|
[9] |
Longo G A, Gasparella A. Experimental and theoretical analysis of heat and mass transfer in a packed column dehumidifier/regenerator with liquid desiccant[J].International Journal of Heat and Mass Transfer, 2005, 48(25/26): 5240-5254
|
[10] |
Lazzarin R M, Gasparella A, Longo G A. Chemical dehumidification by liquid desiccant: theory and experiment[J]. International Journal of Refrigeration, 1999, 22(4): 334-347
|
[11] |
Elsarrag E, Ali Elsheikh E M, Jain Sanjeev. Mass transfer correlations for dehumidification of air by triethylene glycol in a structured packed column[J]. Industrial and Engineering Chemistry Research, 2004, 39: 7676-7681
|
[12] |
Potnis S V, Lenz T G. Dimensionless mass-transfer correlations for packed bed liquid-desiccant contactors[J]. Ind. Eng. Chem. Res., 1996, 35: 4185-4193
|
[13] |
Yin Y G, Zhang X S, Chen Z Q. Experimental study on dehumidifier and regenerator of liquid desiccant cooling air conditioning system[J]. Building and Environment, 2007, 42(7): 2505-2511
|
[14] |
Longo G A, Gasparella A. Experimental analysis on desiccant regeneration in a packed column with structured and random packing[J]. Solar Energy, 2009, 83(4): 511-521
|