CIESC Journal ›› 2021, Vol. 72 ›› Issue (10): 5132-5141.DOI: 10.11949/0438-1157.20210484

• Fluid dynamics and transport phenomena • Previous Articles     Next Articles

Experimental research on influence of abnormal shape on heat transfer performance of copper-water heat pipe

Lei ZHANG1,2(),Ye DAI1,2,Xingwei CHEN1,Jie ZHANG1,Yang ZOU1,2()   

  1. 1.Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800, China
    2.University of Chinese Academy of Sciences, Beijing 100049, China
  • Received:2021-04-08 Revised:2021-07-23 Online:2021-10-05 Published:2021-10-05
  • Contact: Yang ZOU

折弯异型对铜-水热管传热性能影响的实验研究

张磊1,2(),戴叶1,2,陈兴伟1,张洁1,邹杨1,2()   

  1. 1.中国科学院上海应用物理研究所,上海 201800
    2.中国科学院大学,北京 100049
  • 通讯作者: 邹杨
  • 作者简介:张磊(1996—),男,博士研究生,972336283@qq.com
  • 基金资助:
    中国科学院战略性先导科技专项项目(XDA02010000);中国科学院前沿科学重点研究项目(QYZDY-SSW-JSC016);中国科学院上海应用物理研究所育新计划项目(Y955051031)

Abstract:

In order to study the influence of abnormal shape on the performance of heat pipes, three copper-water heat pipes were experimentally studied. The heating temperature range is 50—90℃, and the cooling water flow range is 40—104 L/h. Comparing the starting performance and isothermal performance under different working conditions, the results show that abnormal-shaped pipes may appear “temperature hysteresis” phenomenon when the heating temperature is low, which significantly increases the start-up time, but the start-up time of all working conditions is within 4 min; the abnormal shape makes the isothermal performance of the heat pipe worse but it is still within the acceptable range. The maximum heat transfer power, the heat transfer resistance of the evaporation section, and the overall thermal resistance under different application conditions have been studied. The experiment shows that when the heating temperature is low, the special shape has a greater influence on the maximum heat transfer power and heat transfer resistance. When the heating temperature is greater than 80℃, the maximum heat transfer power difference between the special shape tube and the straight tube is reduced to 30%, and the heat transfer resistance at this time reaches the level of 10-2.

Key words: heat pipe, abnormal shape, heat transfer, thermal resistance, evaporation, condensation

摘要:

为了研究异型对于热管性能的影响,对三支铜-水热管进行了实验研究。加热温度范围为50~90℃,冷却水流量范围为40~104 L/h,对比不同工况下的启动性能、等温性能,结果表明,异型管在加热温度较低时可能出现“温度滞后”现象,从而使启动时间显著增加;异型使得热管等温性能变差但仍在可接受的范围内。对不同应用条件下的最大传热功率、蒸发段传热热阻、整体热阻进行了研究,实验表明:加热温度较低时,异型对于最大传热功率及传热热阻的影响较大,当加热温度大于80℃时,异型管与直管之间最大传热功率的差值缩小到30%以内,且此时的传热热阻达到10-2量级水平。

关键词: 热管, 异型, 传热, 热阻, 蒸发, 凝结

CLC Number: