[1] |
AGNEW B, AMELI S M. A finite time analysis of a cascade refrigeration system using alternative refrigerants [J]. Applied Thermal Engineering, 2004, 24: 2557-2565.
|
[2] |
WALIMBE N S, NARAYANKHEDKAR K G, ATREY M D. Experimental investigation on mixed refrigerant Joule -Thomson cryocooler with flammable and non-flammable refrigerant mixtures [J]. Cryogenics, 2010, 50: 653-659.
|
[3] |
芮胜军,张华,张庆钢,等. 两级分凝自复叠制冷系统特性[J]. 化工学报, 2013, 64(6): 2029-2035. DOI: 10.3969/j.issn.0438-1157. 2013.06.018.
|
|
RUI S J, ZHANG H, ZHANG Q G, et al. Characteristic study of two-stage segregation auto-cascade refrigeration system [J]. CIESC Journal, 2013, 64(6): 2029-2035. DOI: 10.3969/j.issn.0438-1157. 2013.06.018.
|
[4] |
VENKATARATHNAM G. Cryogenic Mixed Refrigerant Processes [M]. Berlin: Springer Press, 2008.
|
[5] |
MISSIMER D J. Refrigerant conversion of auto-refrigeration cascade (ARC) system [J]. International Journal of Refrigeration, 1997, 20(3): 201-207.
|
[6] |
MAYTAL B Z, PFOTENHAUER J M. Miniature Joule-Thomson Cryocooling [M]. Berlin: Springer Press, 2012.
|
[7] |
MAYTAL B Z, NELLIS G F, KLEIN S A, et al. Elevated-pressure mixed-coolants Joule-Thomson cryocooling [J]. Cryogenics, 2006, 46:55-67.
|
[8] |
YU J L. Improving the performance of small Joule -Thomson cryocooler [J]. Cryogenics, 2008, 48: 426-431.
|
[9] |
RUI S J, ZHANG H, ZHANG B H, et al. Experimental investigation of the performance of a single-stage auto-cascade refrigerator [J]. Heat Mass Transfer, 2016, 52: 11-20.
|
[10] |
杜垲, 徐卫荣. R134a/R123自然复叠式热泵系统浓度配比分析[J]. 制冷学报, 2009, 30(2): 32-38. DOI: 0253-4339(2009)02-0033-06.
|
|
DU K, XU W R. Concentration optimization of R134a/R123 in auto-cascade heat pump systems [J]. Journal of Refrigeration, 2009, 30(2): 32-38. DOI: 0253-4339(2009)02-0033-06.
|
[11] |
GONG M Q, SUN Z H, WU J F, et al. Performance of R170 mixtures as refrigerants for refrigeration at -80℃ temperature range [J]. International Journal of Refrigeration, 2009, 32: 892-900.
|
[12] |
GONG M Q, WU J F, LUO E C. Performances of the mixed-gases Joule-Thomson refrigeration cycles for cooling fixed-temperature heat loads [J]. Cryogenics, 2004, 44: 847-857.
|
[13] |
GONG M Q, WU J F, LUO E C, et al. Study of the single-stage mixed-gases refrigeration cycle for cooling temperature-distributed heat loads [J]. International Journal of Thermal Sciences, 2004, 43: 31-41.
|
[14] |
VENKATARATHNAM G, MOKASHI G, MURTHY S S. Occurrence of pinch points in condensers and evaporators for zeotropic refrigerant mixtures [J]. International Journal of Refrigeration, 1996, 19(6): 361-368.
|
[15] |
NAYAK H G, VENKATARATHNAM G. Performance of an auto refrigerant cascade refrigerator operating in gas refrigerant supply (GRS) mode with nitrogen-hydrocarbon and argon hydrocarbon refrigerants [J]. Cryogenics, 2009, 49: 350-359.
|
[16] |
VENKATARATHNAM G, MURTHY S S. Effect of mixture composition on the formation of pinch points in condensers and evaporators for zeotropic refrigerant mixtures [J]. International Journal of Refrigeration, 1999, 22: 205-215.
|
[17] |
WANG Q, LI D H, WANG J P, et al. Numerical investigations on the performance of a single-stage auto-cascade refrigerator operating with two vapor-liquid separators and environmentally benign binary refrigerants [J]. Applied Energy, 2013, 112: 949-955.
|
[18] |
WANG Q, CUI K, SUN T F, et al. Performance of a single-stage auto-cascade refrigerator operating with a rectifying column at the temperature level of -60℃ [J]. Journal of Zhejiang University, 2011, 12(2): 139-145.
|
[19] |
WANG Q, LIU R, WANG J P, et al. An investigation of the mixing position in the recuperators on the performance of an auto-cascade refrigerator operating with a rectifying column [J]. Cryogenics, 2012, 52: 581-589.
|
[20] |
KIM S G, KIM M S. Experiment and simulation on the performance an auto-cascade refrigeration system using carbon dioxide as a refrigerant [J]. International Journal of Refrigeration, 2002, 25: 1093-1101.
|