化工学报 ›› 2005, Vol. 56 ›› Issue (10): 1880-1886.

• 多相流 • 上一篇    下一篇

单孔及微孔曝气低气速鼓泡床内气泡行为比较

梁斌;胡强;周慧;张全忠;沈伟   

  1. 四川大学化工学院,四川省多相流传质与反应工程重点实验室,四川 成都 610065
  • 出版日期:2005-10-25 发布日期:2005-10-25

Comparison of bubble behavior between single orifice and porous spargers air-water bubble columns

LIANG Bin;HU Qiang;ZHOU Hui;ZHANG Quanzhong;SHEN Wei   

  • Online:2005-10-25 Published:2005-10-25

关键词: 鼓泡床, 气泡, 分布器, 传质

Abstract: Bubble dispersion greatly relies on spargers. Single orifice and porous spargers were tested inside a bubble column under a low gas throughput to study their influences on gas dispersion and gas-liquid interface area. A PBE model without considering the effect of bubble coalescence was developed to describe axial bubble distribution. Both simulation and experimental results showed that bubbles broke up much faster than coalesced under low gas velocity. For a single orifice sparger, breakage was a dominant feature for bubbles after they left the orifice. Initial bubbles formed over the orifice were mostly larger than the largest stable bubble. They broke up quickly and their sizes were reduced below the maximum diameter ds of stable bubbles. In contrast, a porous sparger produced a large amount of initial bubbles smaller than the largest stable bubble. The bubbles possessed smaller size and narrower distribution compared with the bubbles obtained by single orifice spargers. With the porous sparger, gas-liquid surface area was increased by 5—6 times even though the gas holdup changed insignificantly. High mass transfer area could be obtained by injecting more small initial bubbles with diameters under ds.

Key words: 鼓泡床, 气泡, 分布器, 传质