化工学报 ›› 2012, Vol. 63 ›› Issue (5): 1385-1390.DOI: 10.3969/j.issn.0438-1157.2012.05.009

• 流体力学与传递现象 • 上一篇    下一篇

环冷机分层布料仿真与优化

张家元1,田万一1,2,戴传德2,张小辉1   

  1. 1中南大学能源科学与工程学院;2中冶长天国际工程有限责任公司
  • 收稿日期:2011-10-18 修回日期:2012-02-22 出版日期:2012-05-05 发布日期:2012-05-05
  • 通讯作者: 田万一

Simulation and optimization of sinter circular cooler layer-loading

ZHANG Jiayuan1,TIAN Wanyi1,2,DAI Chuande2,ZHANG Xiaohui1   

  1. 1School of Energy Science and Engineering,Central South University;2Zhongye Changtian International Engineering Co.,Ltd.
  • Received:2011-10-18 Revised:2012-02-22 Online:2012-05-05 Published:2012-05-05

摘要: 以提高环冷机“余热利用区”出口烟气温度和环冷机的余热回收利用率为目标,对某钢铁企业420 m2环冷机进行了分层布料仿真实验研究。以多孔介质模型为基础,结合Fluent软件的UDF和UDS功能,建立气、固局部非热力学平衡的双能量方程模型,以Fluent软件为计算平台,建立了烧结矿冷却过程求解的数学模型。利用该模型对不同的分层布料工况及常规布料工况进行了模拟计算,得到了最优分层布料参数。研究结果表明,按粒度对环冷机烧结矿实行分层布料可有效提高环冷机“余热利用区”出口烟气温度和环冷机的余热回收利用量,余热回收利用量比常规工况提高了23.2%,出口烟气平均温度比常规工况提高了43.72 K。

关键词: 烧结, 环冷机, 分层布料, 数值模拟, 优化

Abstract: To increase the flue gas temperature of outlet and waste heat recovery efficiency in the waste heat recovery area,a simulation study on sinter circular cooler layer-loading is carried out in a 420 m2 sinter circular cooler in an iron and steel company.Based on the porous medium model and the standard k-ε turbulence model,the two-equation energy model of non-equilibrium thermodynamics is set up with the user-defined-scalar (UDS)and user-defined-function (UDF)of Fluent.A mathematical model of sinter cooling process is established with the computing platform of Fluent.The optimal parameters were obtained by simulating different conditions of layer-loading and general-loading with the mathematical model.The optimal parameters are as follows:the height,porosity and size of bottom layer are 0.4 m,0.4 and 0.035 m,respectively; the height,porosity and size of middle layer are 0.5 m,0.3 and 0.025 m,respectively; those of top layer are 0.5 m,0.3 and 0.03 m; the gas velocity of inlet is 7.65 m·s-1,and the gas temperature of inlet is 404 K.The results show that compared with the general-loading,the layer-loading used in the sinter circular cooler can increase the flue gas temperature at outlet by 43.72 K,and increase the waste heat recovery efficiency by 23.2% in waste heat recovery area.

Key words: sinter, sinter circular cooler, layer-loading, simulation, optimization