化工学报 ›› 2020, Vol. 71 ›› Issue (5): 2017-2023.DOI: 10.11949/0438-1157.20191553

• 流体力学与传递现象 • 上一篇    下一篇

Cu含量对Al-Cu-Si合金相变储热性能的影响

石彦1(),赵君文1(),袁艳平2,戴光泽1,韩靖1   

  1. 1.西南交通大学材料科学与工程学院,四川 成都 610031
    2.西南交通大学机械工程学院,四川 成都 610031
  • 收稿日期:2019-12-19 修回日期:2020-03-04 出版日期:2020-05-05 发布日期:2020-05-05
  • 通讯作者: 赵君文
  • 作者简介:石彦(1993—),男,硕士,研究生,swjtu_shiyan@foxmail.com
  • 基金资助:
    四川省应用基础重点研究项目(2017JY0253);汽车高性能材料及成形技术四川省高校重点实验室开放项目(szjj2017-019)

Effect of Cu content on phase change thermal storage properties of Al-Cu-Si alloy

Yan SHI1(),Junwen ZHAO1(),Yanping YUAN2,Guangze DAI1,Jing HAN1   

  1. 1.School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu 610031, Sichuan, China
    2.School of Mechanical Engineering, Southwest Jiaotong University, Chengdu 610031, Sichuan, China
  • Received:2019-12-19 Revised:2020-03-04 Online:2020-05-05 Published:2020-05-05
  • Contact: Junwen ZHAO

摘要:

Al-Cu-Si基相变材料具有成本低、相变潜热高、抗氧化性能高等优势,是最具潜力的太阳能储存材料之一。而Cu含量对其储热性能特别是体积潜热有重要影响,但相关研究未见报道。通过差示扫描量热仪和激光热导分析仪研究了Al-Cu-Si合金的相变温度、质量潜热和体积潜热随Cu含量变化的关系,以及比热容、热扩散率和热导率等随温度变化的关系。研究结果表明,在Cu含量35%~55%时,Al-Cu-Si合金相变温度为512.5~604.2℃,质量潜热为354.4~458.1 J?g-1,体积潜热为1524.1~1763.8 J?cm-3。质量潜热和体积潜热均随着Cu含量的增加呈现出“双峰型”的变化趋势,Cu含量42%时质量潜热最大,为458.1 J?g-1;Cu含量48%时体积潜热最大,为1763.8 J?cm-3。Al-Cu-Si合金的热导率随着Cu含量的增加而降低,且在500℃时Al-Cu-Si合金的热导率为91.4~137.5 W?m-1?K-1。综合研究表明,Al-Cu-Si合金在太阳能储热领域具有很高的应用价值。

关键词: 太阳能, 相变, Al-Cu-Si合金, 潜热, 热导率

Abstract:

With the advantages of low cost, high phase change latent heat, and high oxidation resistance, Al-Cu-Si alloy phase change materials (PCMs) are considered as one of the most promising solar energy storage materials. The content of Cu has an important effect on its heat storage performance, especially the volume latent heat. However, to the knowledge of the authors, no previous study has been reported. In this work, we studied the relationships between the Cu content and phase change temperature, mass latent heat, volume latent heat of Al-Cu-Si alloy, as well as the evolution of specific heat, thermal diffusivity, and thermal conductivity vs. the temperature, respectively, according to the differential scanning calorimetry and laser thermal conductivity analyzer. The results showed that for the Al-Cu-Si alloy with 35%—55%Cu, the phase change temperature of Al-Cu-Si alloy is 512.5—604.2℃, the mass latent heat is 354.4—458.1 J?g-1, and the volume latent heat is 1524.1—1763.8 J?cm-3. Meanwhile, both the mass latent heat and the volume latent heat showed a “bimodal” trend with the increase of Cu content. When the Cu content is 42%, the highest mass latent heat is 458.1 J?g-1, while the highest volume latent heat is 1763.8 J?cm-3, corresponding to 48%Cu content. Furthermore, with the increase of Cu content, the thermal conductivity of Al-Cu-Si alloy decreased in the range of 91.4 —137.5 W?m-1?K-1 at 500°C. Comperehensive research shows that Al-Cu-Si alloy has high application value on the field of solar thermal storage.

Key words: solar energy, phase change, Al-Cu-Si alloy, latent heat, thermal conductivity

中图分类号: