[1] |
Shonder J A,Beck J V.Field test of a new method for determining soil formation thermal conductivity and borehole resistance[J].ASHRAE Transactions,1999,106(2):843-850
|
[2] |
Hellstrom G.thermal analysis of duct storage systems[D].Lund,Sweden:University of Lund,1991
|
[3] |
Lamarche L,Beauchamp B.New solutions for the short-time analysis of geothermal vertical boreholes[J].Int. J.Heat Mass Transfer,2007,50(3):1408-1419
|
[4] |
Bandyopadhyay G,Gosnold W,Mann M.Analytical and semi-analytical solutions for short-time transient response of ground heat exchangers[J].Energy and Buildings,2008,40(3):1816-1824
|
[5] |
Muraya N K,O-Neal D L,Heffington W M.Thermal interference of adjacent legs in a vertical U-tube heat exchanger for a ground-coupled heat pump[J].ASHRAE Transactions,1996,102(2):12-21
|
[6] |
Shen Guomin(沈国民),Zhang Hong(张虹).Parametric analysis of thermal interference in vertical U-tube heat exchangers for GCHP[J].Acta Energiae Solaris Sinica(太阳能学报).2007,28(6):604-607
|
[7] |
Wang Tao(王韬),Yu Yuejin(余跃进),Xia Chen(夏晨).Influence of adding heat insulation baffle on heat transfer performance of vertical U-tube ground heat exchanger[J].Building Science(建筑科学),2011,27(10):93-96
|
[8] |
American Society of Heating,Refrigerating and Air-Conditioning Engineers.ASHRAE Handbook HVAC Applications[M].Atlanta:ASHRAE Inc.,2003:1425
|
[9] |
Oppelt Thomas,Riehl Ingo,Gross Ulrich.Modeling of the borehole filling of double U-pipe heat exchangers[J].Geothermics,2010,39(2):270-276
|
[10] |
Lamarche L,Kajl S,Beauchamp B.A review of methods to evaluate borehole thermal resistances in geothermal heat-pump systems[J].Geothermics,2010,39(1):187-200
|
[11] |
Gehlin S,Hellstrm G.Comparison of four models for thermal response test evaluation[J].ASHRAE Transactions,2003,109(1):131-142
|
[12] |
Fujii H,Okubo H,Itoi R.Thermal response tests using optical fiber thermometers[J].Geothermal Resources Council Transactions,2006,30(4)545-551
|
[13] |
Fujii H,Okubo H,Nishi K,et al.An improved thermal response test for U-tube ground heat exchanger based on optical fiber thermometers[J].Geothermics,2009,38(4):399-406
|
[14] |
Sharqawy M H,Mokheimer E M,Badr H M.Effective pipe-to-borehole thermal resistance for vertical ground heat exchangers[J].Geothermics,2009,38(2):271-27
|
[15] |
Incropera F P,Dewitt D P.Fundamentals of Heat and Mass Transfer[M].5th ed.New York:John Wiley & Sons Inc.,2002:981
|
[16] |
Kavanaugh S P.Field tests for ground thermal properties methods and impact on ground-source heat pump design[J].ASHRAE Transactions,2000,106(4):851-855
|
[17] |
Yu Xin(于新),Lian Zhiwei(连之伟),Chen Jianping(陈建萍).The modified integrated cylindrical source model[J].Journal of Shanghai Jiao Tong University(上海交通大学学报),2010,44(10):1337-1339
|
[18] |
Marcotte D,Pasquier P.On the estimation of thermal resistance in borehole thermal conductivity test[J].Renewable Energy,2008,33(5):2407-2415
|
[19] |
Zeng H,Diao N,Fang Z.Heat transfer analysis of boreholes in vertical ground heat exchangers[J].Int. J.Heat Mass Transfer,2003,46:4467-4481
|